Air Mixing Solutions for Commercial HVAC Systems
Eliminate Air Stratification. Protect Coils. Improve HVAC Performance.
Common HVAC Problems We Solve
- Nuisance freeze-stat trips caused by cold air stratification.
- Frozen heating or cooling coils resulting in expensive repairs.
- Poor outside air and return air mixing.
- Uneven mixed-air temperatures that reduce comfort and efficiency.
- Limited air handler footprint for traditional mixing sections.
- Inefficient economizer operation and increased energy costs.
What Causes Freeze-Stat Trips?
A freeze-stat protects the heating coil from freezing. Even if the average mixed-air temperature is above freezing, cold streaks of outside air can strike one section of the coil before the air has fully mixed. The freeze-stat senses this localized cold air and shuts down the unit to protect the coil. Proper air mixing eliminates these cold pockets and significantly reduces nuisance trips.
Channel Blender®
The Channel Blender® is a patented air mixing device that mechanically redistributes outside air and return air into alternating channels. This creates rapid, uniform mixing before the air reaches the heating or cooling coil.
- Eliminates air stratification
- Reduces nuisance freeze-stat trips
- Protects heating and cooling coils
- Reduces mixing section length by up to 50%
- Improves temperature uniformity
- Improves sensor accuracy
- Lowers pressure drop compared to traditional static mixing sections
- Suitable for both new air handlers and retrofit applications
- Helps extend economizer operating hours
Industries Served
- Higher Education
- Healthcare
- Laboratories
- K-12 Schools
- Industrial Manufacturing
- Government Facilities
- Commercial Buildings
- Data Centers
Applications
-
Custom Air Handling Units
-
Make-Up Air Units
-
Laboratory AHUs
-
Healthcare AHUs
-
Industrial ventilation systems
-
Retrofit applications for existing AHUs
Applications
-
Custom Air Handling Units
-
Make-Up Air Units
-
Laboratory AHUs
-
Healthcare AHUs
-
Industrial ventilation systems
-
Retrofit applications for existing AHUs
Frequently Asked Questions
What causes freeze-stat trips?
Can the Channel Blender be installed in an existing air handler?
Does the Channel Blender reduce energy consumption?
Can Blender Products Channel Blenders be incorporated into any new air handling unit?
Which industries benefit the most?
Why is air mixing important?
Improve Air Mixing. Reduce Energy. Protect Your Equipment.
Whether you’re designing a new air handling unit or solving chronic freeze-stat issues, Lumin-Air can evaluate your application and recommend the best air mixing solution. Contact Lumin-Air today to schedule an Air Mixing Evaluation.